ELISA Kits

Lablisa® AA (Arachidonic Acid) ELISA Kit

Catalog No.: LAB13382
Competitive
ReactivityUniversal
Detection Range3.13-200 μg/mL
Sensitivity0.94 μg/mL
₹32,550.00
This product is currently out of stock
Dispatch: Usually dispatched within 5–10 working days

Description

This ELISA kit uses the Competitive-ELISA principle. The micro-ELISA plate provided in this kit has been pre-coated with AA. During the reaction, AA in the sample or standard competes with a fixed amount of AA on the solid phase supporter for sites on the Biotinylated Detection Ab specific to AA. Excess conjugate and unbound sample or standard are washed away, and Avidin-Horseradish Peroxidase (HRP) conjugate are added to each micro plate well and incubated. Then a TMB substrate solution is added to each well. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns from blue to yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm. The concentration of AA in tested samples can be calculated by comparing the OD of the samples to the standard curve.

Technical Specifications

Catalog NumberLAB13382
ReactivityUniversal
Detection Range3.13-200 μg/mL
Sensitivity0.94 μg/mL

Product Overview

Product name:

Lablisa® AA (Arachidonic Acid) ELISA Kit
Reactivity:Universal
Alternative Names:ARA
Assay Type:Competitive
Sensitivity:0.94 μg/mL
Standard:200 μg/mL
Range:3.13-200 μg/mL
Sample Type:Serum, Plasma and Tissue homogenate and  other biological samples;Sample volume:25μL
Assay Length:1.5H
Research Area:Signal transduction;Metabolic pathway;Endocrinology;Neuro science;Hormone metabolism;Bone metabolism;

Standard curve

Concentration (ng/mL)OD
2000.231
1000.348
500.62
250.983
12.51.181
6.251.46
3.131.833
02.559

Precision

Intra-assay Precision (Precision within an assay) :CV%<8% Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays) :CV%<10% Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.


Recovery

Matrices listed below were spiked with certain level of recombinant AA and the recovery rates were calculated by comparing the measured value to the expected amount of AA in samples.

MatrixRecovery rangeAverage
serum (n=8)97-103%100%
EDTA plasma (n=8)87-95%91%
Cell culture media (n=8)88-97%92%


Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of AA and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Matrix1:21:41:81:16
serum (n=8)95-101%96-104%89-96%89-95%
EDTA plasma (n=8)96-103%96-103%96-105%88-96%
Cell culture media (n=8)91-100%95-101%98-104%96-106%

Manuals on the web are for your reference only, specifications are subject to the delivery manuals.

Product Images

Lablisa® AA (Arachidonic Acid) ELISA Kit

Documents

Datasheet
Download

Protocol

For detailed protocol, assay guidance, and technical support, please contact our Customer Support team at
support@labrecon.in

Publications

Avialable Soon...

Customer Reviews

0.0
  • Star
  • Star
  • Star
  • Star
  • Star
Based on 0 reviews

Share your experience with this product to help other researchers.

Login to Submit a Review

No reviews yet. Be the first to share your experience!