ELISA Kits

Lablisa® Human Ang-Ⅱ (Angiotensin Ⅱ) ELISA Kit

Catalog No.: LAB10870
Competitive
ReactivityHuman
Detection Range31.25-2000pg/mL
Sensitivity18.75pg/mL
₹32,550.00
Dispatch: Usually dispatched within 5–10 working days

Description

This ELISA kit uses the Competitive-ELISA principle. The micro-ELISA plate provided in this kit has been pre-coated with Human Ang-Ⅱ. During the reaction, Human Ang-Ⅱ in the sample or standard competes with a fixed amount of Human Ang-Ⅱ on the solid phase supporter for sites on the Biotinylated Detection Ab specific to Human Ang-Ⅱ. Excess conjugate and unbound sample or standard are washed away, and Avidin-Horseradish Peroxidase (HRP) conjugate are added to each micro plate well and incubated. Then a TMB substrate solution is added to each well. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns from blue to yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm. The concentration of Human Ang-Ⅱ in tested samples can be calculated by comparing the OD of the samples to the standard curve.

Technical Specifications

Catalog NumberLAB10870
ReactivityHuman
Detection Range31.25-2000pg/mL
Sensitivity18.75pg/mL

Product Overview

Product name:

Lablisa® Human Ang-Ⅱ (Angiotensin Ⅱ) ELISA Kit
Reactivity:Human
Alternative Names:Angiotensin-2
Assay Type:Competitive
Sensitivity:18.75pg/mL
Standard:2000pg/mL
Range:31.25-2000pg/mL
Sample Type:Serum, Plasma and Tissue homogenate and  other biological samples;Sample volume:25μL
Assay Length:1.5H
Research Area:Endocrinology;Reproductive science;Hormone metabolism;

Standard curve

Concentration (pg/mL)OF
20000.237
10000.335
5000.68
2500.885
1251.111
62.51.679
31.251.886
02.677

Precision

Intra-assay Precision (Precision within an assay) :CV%<8% Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays) :CV%<10% Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.


Recovery

Matrices listed below were spiked with certain level of recombinant Human Ang-Ⅱ and the recovery rates were calculated by comparing the measured value to the expected amount of Human Ang-Ⅱ in samples.

MatrixRecovery rangeAverage
serum (n=8)94-102%98%
EDTA plasma (n=8)90-98%95%
Cell culture media (n=8)94-104%99%


Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Human Ang-Ⅱ and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Matrix1:21:41:81:16
serum (n=8)98-105%99-106%88-97%93-99%
EDTA plasma (n=8)96-103%95-103%94-102%96-103%
Cell culture media (n=8)94-101%94-103%98-105%89-98%

Manuals on the web are for your reference only, specifications are subject to the delivery manuals.

Product Images

Lablisa® Human Ang-Ⅱ (Angiotensin Ⅱ) ELISA Kit

Documents

Datasheet
Download

Protocol

For detailed protocol, assay guidance, and technical support, please contact our Customer Support team at