This ELISA kit uses the Competitive-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with Human CTX-Ⅲ. During the reaction, Human CTX-Ⅲ in the sample or standard competes with a fixed amount of Human CTX-Ⅲ on the solid phase supporter for sites on the Biotinylated Detection Ab specific to Human CTX-Ⅲ. Excess conjugate and unbound sample or standard are washed away, and Avidin-Horseradish Peroxidase (HRP) conjugate are added to each micro plate well and incubated. Then a TMB substrate solution is added to each well. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns from blue to yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm. The concentration of Human CTX-Ⅲ in tested samples can be calculated by comparing the OD of the samples to the standard curve.

Technical Specifications

Catalog NumberLAB9616
ReactivityHuman
Detection Range0.16-10ng/mL
Sensitivity0.1ng/mL

Product Overview

Product name:

Lablisa® Human CTX-Ⅲ (Cross Linked C-telopeptide of Type Ⅲ Collagen) ELISA Kit
Reactivity:Human
Alternative Names:COL3A1, EDS4A, collagen type III alpha 1, collagen type III alpha 1 chain, EDSVASC
Assay Type:Competitive
Sensitivity:0.1ng/mL
Standard:10ng/mL
Range:0.16-10ng/mL
Sample Type:Serum, Plasma and Tissue homogenate and  other biological samples;Sample volume:25μL
Assay Length:1.5H
Research Area:Cardiovascular biology;

Standard curve

Concentration (pg/mL)OD
100.241
50.321
2.50.631
1.250.933
0.631.173
0.311.615
0.161.926
02.73

Precision

Intra-assay Precision (Precision within an assay) CV%<8% Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays) CV%<10% Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.


Recovery

Matrices listed below were spiked with certain level of recombinant Human CTX-Ⅲ and the recovery rates were calculated by comparing the measured value to the expected amount of Human CTX-Ⅲ in samples.

MatrixRecovery rangeAverage
serum(n=8)89-99%94%
EDTA plasma(n=8)90-97%93%
Cell culture media (n=8)86-95%90%


Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Human CTX-Ⅲ and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Matrix1:21:41:81:16
serum(n=8)89-98%95-104%93-102%95-101%
EDTA plasma(n=8)93-100%95-104%99-106%97-105%
Cell culture media (n=8)95-105%88-96%89-98%98-106%

Manuals on the web are for your reference only, specifications are subject to the delivery manuals.

Product Images

Lablisa® Human CTX-Ⅲ (Cross Linked C-telopeptide of Type Ⅲ Collagen) ELISA Kit

Documents

Datasheet
Download

Protocol

For detailed protocol, assay guidance, and technical support, please contact our Customer Support team at
support@labrecon.in

Publications

Available Soon...

Customer Reviews

0.0
  • Star
  • Star
  • Star
  • Star
  • Star
Based on 0 reviews

Share your experience with this product to help other researchers.

Login to Submit a Review

No reviews yet. Be the first to share your experience!

Feedback & Reviews