Lablisa® Human OXA (Orexin A) ELISA Kit

Catalog No.: LAB9696
Competitive
ReactivityHuman
Detection Range62.5-4000pg/mL
Sensitivity37.5 pg/mL
₹32,550.00
Dispatch: Usually dispatched within 5–10 working days

Description

This ELISA kit uses the Competitive-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with Human OXA. During the reaction, Human OXA in the sample or standard competes with a fixed amount of Human OXA on the solid phase supporter for sites on the Biotinylated Detection Ab specific to Human OXA. Excess conjugate and unbound sample or standard are washed away, and Avidin-Horseradish Peroxidase (HRP) conjugate are added to each micro plate well and incubated. Then a TMB substrate solution is added to each well. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns from blue to yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm. The concentration of Human OXA in tested samples can be calculated by comparing the OD of the samples to the standard curve.

Technical Specifications

Catalog NumberLAB9696
ReactivityHuman
Detection Range62.5-4000pg/mL
Sensitivity37.5 pg/mL

Product Overview

Product name:

Lablisa® Human OXA (Orexin A) ELISA Kit
Reactivity:Human
Alternative Names:Hypocretin-1, Orexin A, HCRT1, Hcrt ; Hcrt1 ; Hypocretin ; Hypocretin neuropeptide precursor ; Hypocretin-1 ; OREX ; Orexin precursor ; OX ; PPOX
Assay Type:Competitive
Sensitivity:37.5 pg/mL
Standard:4000pg/mL
Range:62.5-4000pg/mL
Sample Type:Serum, Plasma and Tissue homogenate and  other biological samples;Sample volume:25μL
Assay Length:1.5H
Research Area:Signal transduction;Infection immunity;

Standard curve

Concentration (pg/mL)OD
40000.234
20000.336
10000.665
5000.845
2501.264
1251.538
62.52.085
02.65

Precision

Intra-assay Precision (Precision within an assay) CV%<8% Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays) CV%<10% Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.


Recovery

Matrices listed below were spiked with certain level of recombinant Human OXA and the recovery rates were calculated by comparing the measured value to the expected amount of Human OXA in samples.

MatrixRecovery rangeAverage
serum(n=8)95-102%98%
EDTA plasma(n=8)94-104%99%
Cell culture media (n=8)91-99%94%


Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Human OXA and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Matrix1:21:41:81:16
serum(n=8)90-99%99-106%88-96%93-101%
EDTA plasma(n=8)89-97%98-104%96-105%90-98%
Cell culture media (n=8)95-104%94-101%99-107%98-105%

Manuals on the web are for your reference only, specifications are subject to the delivery manuals.

Product Images

Lablisa® Human OXA (Orexin A) ELISA Kit

Documents

Datasheet
Download

Protocol

For detailed protocol, assay guidance, and technical support, please contact our Customer Support team at
support@labrecon.in

Publications

Available Soon...

Customer Reviews

0.0
  • Star
  • Star
  • Star
  • Star
  • Star
Based on 0 reviews

Share your experience with this product to help other researchers.

Login to Submit a Review

No reviews yet. Be the first to share your experience!

Feedback & Reviews