| Reactivity | Mouse |
| Detection Range | 7.82-500pg/mL |
| Sensitivity | 4.69pg/mL |
This ELISA kit uses the Competitive-ELISA principle. The micro-ELISA plate provided in this kit has been pre-coated with Mouse SST. During the reaction, Mouse SST in the sample or standard competes with a fixed amount of Mouse SST on the solid phase supporter for sites on the Biotinylated Detection Ab specific to Mouse SST. Excess conjugate and unbound sample or standard are washed away, and Avidin-Horseradish Peroxidase (HRP) conjugate are added to each micro plate well and incubated. Then a TMB substrate solution is added to each well. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns from blue to yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm. The concentration of Mouse SST in tested samples can be calculated by comparing the OD of the samples to the standard curve.
| Catalog Number | LAB11721 |
| Reactivity | Mouse |
| Detection Range | 7.82-500pg/mL |
| Sensitivity | 4.69pg/mL |
Product name: | Lablisa® Mouse SST(Somatostatin) ELISA Kit |
| Reactivity: | Mouse |
| Alternative Names: | GHIH, SRIF, SMST, GHRIH, GHRIF, Growth Hormone Releasing Inhibiting Hormone, Somatotropin Release-Inhibiting Factor, Somatostatin-14, Somatostatin-28 |
| Assay Type: | Competitive |
| Sensitivity: | 4.69pg/mL |
| Standard: | 500pg/mL |
| Range: | 7.82-500pg/mL |
| Sample Type: | Serum, Plasma and Tissue homogenate and other biological samples;Sample volume:25μL |
| Assay Length: | 1.5H |
| Research Area: | Endocrinology;Reproductive science;Neuro science;Genetic science;Hormone metabolism; |
Standard curve
| Concentration (pg/mL) | OF |
|---|---|
| 500 | 0.222 |
| 250 | 0.373 |
| 125 | 0.561 |
| 62.5 | 0.979 |
| 31.25 | 1.28 |
| 15.63 | 1.617 |
| 7.81 | 1.925 |
| 0 | 2.516 |
Precision
Intra-assay Precision (Precision within an assay) :CV%<8% Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays) :CV%<10% Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.
Recovery
Matrices listed below were spiked with certain level of recombinant Mouse SST and the recovery rates were calculated by comparing the measured value to the expected amount of Mouse SST in samples.| Matrix | Recovery range | Average |
|---|---|---|
| serum (n=8) | 94-103% | 99% |
| EDTA plasma (n=8) | 92-101% | 96% |
| Cell culture media (n=8) | 89-96% | 93% |
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Mouse SST and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Matrix | 1:2 | 1:4 | 1:8 | 1:16 |
|---|---|---|---|---|
| serum (n=8) | 89-98% | 89-97% | 97-105% | 92-100% |
| EDTA plasma (n=8) | 90-98% | 92-99% | 92-100% | 96-104% |
| Cell culture media (n=8) | 91-101% | 93-103% | 92-98% | 94-101% |