ELISA Kits

Lablisa® Rat Ang-Ⅱ (Angiotensin Ⅱ) ELISA Kit

Catalog No.: LAB13279
Competitive
ReactivityRat
Detection Range15.63-1000pg/mL
Sensitivity9.38pg/mL
₹32,550.00
This product is currently out of stock
Dispatch: Usually dispatched within 5–10 working days

Description

This ELISA kit uses the Competitive-ELISA principle. The micro-ELISA plate provided in this kit has been pre-coated with Rat Ang-Ⅱ. During the reaction, Rat Ang-Ⅱ in the sample or standard competes with a fixed amount of Rat Ang-Ⅱ on the solid phase supporter for sites on the Biotinylated Detection Ab specific to Rat Ang-Ⅱ. Excess conjugate and unbound sample or standard are washed away, and Avidin-Horseradish Peroxidase (HRP) conjugate are added to each micro plate well and incubated. Then a TMB substrate solution is added to each well. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns from blue to yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm. The concentration of Rat Ang-Ⅱ in tested samples can be calculated by comparing the OD of the samples to the standard curve.

Technical Specifications

Catalog NumberLAB13279
ReactivityRat
Detection Range15.63-1000pg/mL
Sensitivity9.38pg/mL

Product Overview

Product name:

Lablisa® Rat Ang-Ⅱ (Angiotensin Ⅱ) ELISA Kit
Reactivity:Rat
Alternative Names:Angiotensin-2
Assay Type:Competitive
Sensitivity:9.38pg/mL
Standard:1000pg/mL
Range:15.63-1000pg/mL
Sample Type:Serum, Plasma and Tissue homogenate and  other biological samples;Sample volume:25μL
Assay Length:1.5H
Research Area:Apoptosis;

Standard curve

Concentration (ng/mL)OD
10000.202
5000.396
2500.687
1250.927
62.51.144
31.251.533
15.631.821
02.613

Precision

Intra-assay Precision (Precision within an assay) :CV%<8% Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays) :CV%<10% Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.


Recovery

Matrices listed below were spiked with certain level of recombinant Rat Ang-Ⅱ and the recovery rates were calculated by comparing the measured value to the expected amount of Rat Ang-Ⅱ in samples.

MatrixRecovery rangeAverage
serum (n=8)93-100%96%
EDTA plasma (n=8)94-102%99%
Cell culture media (n=8)87-96%91%


Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Rat Ang-Ⅱ and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Matrix1:21:41:81:16
serum (n=8)94-102%97-107%98-105%98-107%
EDTA plasma (n=8)95-101%93-102%91-99%94-102%
Cell culture media (n=8)90-98%98-104%97-105%98-106%

Manuals on the web are for your reference only, specifications are subject to the delivery manuals.

Product Images

Lablisa® Rat Ang-Ⅱ (Angiotensin Ⅱ) ELISA Kit

Documents

Datasheet
Download

Protocol

For detailed protocol, assay guidance, and technical support, please contact our Customer Support team at
support@labrecon.in

Publications

Avialable Soon...

Customer Reviews

0.0
  • Star
  • Star
  • Star
  • Star
  • Star
Based on 0 reviews

Share your experience with this product to help other researchers.

Login to Submit a Review

No reviews yet. Be the first to share your experience!

Feedback & Reviews