| Reactivity | Mouse |
| Detection Range | 1.56-100ng/mL |
| Sensitivity | 0.94 ng/mL |
No description available.
| Catalog Number | LAB12123 |
| Reactivity | Mouse |
| Detection Range | 1.56-100ng/mL |
| Sensitivity | 0.94 ng/mL |
Product name: | Lablisa® Mouse pERK1/2(Phospho Extracellular Signal Regulated Kinase 1/2) ELISA Kit |
| Reactivity: | Mouse |
| Alternative Names: | MAPK3,ERT2,p44-MAPK,MNK1,p44-ERK1,Microtubule-associated protein 2 kinase,Insulin-stimulated MAP2 kinase,MAP kinase isoform p44,Mitogen-activated protein kinase 3,ERK1 |
| Assay Type: | Sandwich |
| Sensitivity: | 0.94 ng/mL |
| Standard: | 100ng/mL |
| Range: | 1.56-100ng/mL |
| Sample Type: | Serum, Plasma and Tissue homogenate and other biological samples;Sample volume:25μL |
| Assay Length: | 3H |
| Research Area: | Signal transduction;Metabolic pathway;Endocrinology;Gastroenterology;Hormone metabolism; |
Standard curve
| Concentration (pg/mL) | OF | Corrected OD |
|---|---|---|
| 100 | 2.362 | 2.311 |
| 50 | 1.56 | 1.509 |
| 25 | 0.957 | 0.906 |
| 12.5 | 0.525 | 0.474 |
| 6.25 | 0.27 | 0.219 |
| 3.13 | 0.155 | 0.104 |
| 1.57 | 0.094 | 0.043 |
| 0 | 0.051 | 0 |
Precision
Intra-assay Precision (Precision within an assay): CV%<8% Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays): CV%<10% Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.
Recovery
Matrices listed below were spiked with certain level of recombinant Mouse pERK1/2 and the recovery rates were calculated by comparing the measured value to the expected amount of Mouse pERK1/2 in samples.
| Matrix | Recovery range | Average |
|---|---|---|
| serum (n=8) | 82-95% | 88% |
| EDTA plasma (n=8) | 94-107% | 100% |
| Cell culture media (n=8) | 87-95% | 91% |
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Mouse pERK1/2 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Matrix | 1:2 | 1:4 | 1:8 | 1:16 |
|---|---|---|---|---|
| serum (n=8) | 85-92% | 87-97% | 83-96% | 95-102% |
| EDTA plasma (n=8) | 87-98% | 87-98% | 88-97% | 91-103% |
| Cell culture media (n=8) | 86-92% | 89-97% | 87-98% | 92-105% |
Manuals on the web are for your reference only, specifications are subject to the delivery manuals.
Available Soon...
Share your experience with this product to help other researchers.
Login to Submit a ReviewNo reviews yet. Be the first to share your experience!